| MCN-11 |
1 |
MCN-11 |
Condensers |
1 |
|
Westinghouse |
Built 1959 / Surface area, ft2: 65,000 / Waterboxes: two, divided / Effective tube length: 28’ 0” / Hotwell Capacity: 3,500 / Heat Exchange, Btu/hr: 475,000,000 (Tubes, tube sheets and heaters removed) |
|
| MCN-21 |
1 |
MCN-21 |
Condensers |
2 |
|
Westinghouse |
(Tubes, tube sheets and heaters removed) |
|
| IAC-11 |
1 |
Air Compressor - 11 Inst. Air Comp. |
Air Compressor |
1 |
Mezz |
Worthington |
Size: 7x7 HBB, L-90313-T// with 25HP motor=Ser #: 7007 |
|
| IAC-12 |
1 |
Air Compressor (IAC-12) |
Air Compressor |
1 |
Mezz |
Worthington |
Size: 7x7 HBB, Ser#: L-90312-T/// with 25HP motor=Ser #: 7007 |
|
| IAC-13 |
1 |
Air Compressor |
Air Compressor |
1 |
Mezz |
Sullair |
Mdl: 16B-75H WCAC, Bom #: 008198-002, Ser. #: 003-67557, 115/125 PSIG.//motor infor = Part #: 010547-200, ser. #: 006-86003712 |
|
| IAC-21 |
1 |
Air Compressor |
Air Compressor |
1 |
Mezz |
Ingersoll-Rand |
Ser. #: CK2484U99268, Mdl: SSR-EP75, Compacity: 332 CFM, Tamp: 101 // with 75HP motor and 1HP fan motor |
|
| SAC-11 |
1 |
Service Air Compressor (Control Cubicle) |
Air Compressor |
1 |
Mezz |
Atlas Copco |
Ser#: 8451411500314, Type: 19000150-03, Volt: 115, Frequency: 60 Hz, Supply Volts: 5751 PH // other tag info= Mdl: GAU507, Ser: ARP745852. |
|
| SAC-12 |
1 |
Service Air Compressor (SAC-12) |
Air Compressor |
1 |
Mezz |
Ingersoll-Rand |
|
|
| AC-41 |
1 |
Air Compressor |
Air Compressor |
4 |
Basement |
Worthington |
Ser#: 344B / size: 6/6/5X5 / mdl: M50 |
|
| IAC-41 |
1 |
Air Compressor |
Air Compressor |
4 |
Basement |
Chicago Pneumatic Tool Co. |
No: 436 / max gas press: 150 / max water press: 175 / size: 7CYL / ser#: 88972 / with 25 HP motor |
|
| IAC-42 |
1 |
Air Compressor |
Air Compressor |
4 |
Basement |
Ingersoll-Rand |
ser#: F0647U90 / mdl: SSR-EP75 / 317 CFM / 125 PSIG / 75 HP / 100 amps |
|
| AD-11 |
2 |
Air Dryer Tanks and 1 controller |
Air Dryer |
1 |
Mezz |
Pneumatic Products Inc. |
300 PSIG @ 450 degrees / Year: 1989 / Ser#: 90810 & 900811 / CRN#: K0838.5612 / Control box Ser#: 90-6DHA-100202-1 |
Serial # 90810, 900811, 90-6DHA-100202-1 |
| AD-41 |
1 |
Regenerative Air Dryer |
Air Dryer |
4 |
Mezz |
Arrow |
ser#: XD604 / mdl: RH219A1AA5A1E1A1 / tank: 764 / SCFM: 1300 / 115/1/60 volts / 0.5 amps |
|
| IAD-41 |
1 |
Instrument Air Dryer |
Air Dryer |
4 |
Basement |
Hankison International |
mdl: F-100 / ser#: 0203-1-72-086 / 100 SCFM @ 100 deg F / MWP: 200 PSIG / 110 volt / 1/2 HP |
|
| IAD-42 |
1 |
Instrument Air Dryer |
Air Dryer |
4 |
Basement |
Hankison International |
mdl: F-100 / ser#: 0203-1-9210-20 / 100 SCFM @ 100 deg F / MWP: 200 PSIG / 110 volt / 1/2 HP |
|
| IAD-43 |
1 |
Instrument Air Dryer |
Air Dryer |
4 |
Basement |
Henderson Engineering |
ser#: H-26518A / mdl: HL-210 DM / "out of service" on AE tag |
|
| AE-11 |
1 |
Air Ejector |
Air Ejector |
1 |
Mezz |
|
|
|
| AE-21 |
1 |
Air Ejector |
Air Ejector |
2 |
Mezz |
? |
With 5 large valves |
|
| APD-11 |
1 |
Air Preheater Drive |
Air Preheater |
1 |
6 |
Air Preheating Corp / Ljungstrom |
Installed 1959 / Heater#: 3422 / Ser#: AP1750 // Faulk name tag = Mdl: 5APC / RPM: 13 / Date: 5/59 / 10 HP/ Ratio: 132.1 |
Mdl: 5APC, Serial #: AP1750 |
| APD-21 |
1 |
Air Preheater Drive |
Air Preheater |
2 |
8 |
Air Preheating Corp / Ljungstrom |
Installed: 196- / Heater#: 3878 / ser#: AP-2017 // Faulk name tag = mdl: 5APC / 13 RPM / Date: 06/62 / Ratio: 132.1 // motor = ser#: 24N3721 / 15 HP. |
|
| APAD-41 |
1 |
Air Preheater Drive |
Air Preheater |
4 |
5 |
Air Preheating Corp / Ljungstrom |
Installed: 1972 / Heater#: 5463 / Type & Size: VX2B / order#: AP3027 / Faulk name tag = mdl: 5APC-B / Date 10/71 / Ratio 132.1 / input RPM: 1750 / output RPM: 13.25 // Motor (GE) = ser#: OFK9A080D46 / 20 HP / 1765 RPM |
|
| AS-11 |
1 |
Air Silencer |
Air Silencer |
1 |
6 |
Beaird |
Mdl: 56 VT-5 / Ser#: 169266-01-2 |
Mdl: 56 VT-5 / Ser#: 169266-01-2 |
| AS-21 |
1 |
Air Silencer |
Air Silencer |
2 |
9 |
Beaird |
Ser#: 16926-01 / mdl: 36VT.3 |
|
| BC-11 |
1 |
Battery Charger #11 |
Batteries & Chargers |
1 |
Mezz |
Electric Products (EP) |
ser#: 8753 / 7.5 HP / 3 phs / 60 cyc / DC volts: 35.7 / 1750 RPM / type: 35D. |
Serial#: 8753 |
| BC-12 |
1 |
Battery Charger #12 |
Batteries & Chargers |
1 |
Mezz |
Electric Products (EP) |
ser#: SC20253A / 7.5 HP / 3 phs / 60 cyc / DC volts: 35.7 / 1750 RPM / type: 35D-206. |
Serial#: SC20253A |
|
1 |
C @ D Battery Charger #11 |
Batteries & Chargers |
1 |
|
C @ D Technologies Inc. |
Model No. ARR130K200F / Serial No. C PS960634 / AC Volts – 480 / AC Amps – 56 / Phase 3 / Frequency – 60 Hz / DC Volts – 132 / DC Amps – 200 / Cells - 60 |
|
| BC-33 |
1 |
Battery Charger #33 |
Batteries & Chargers |
3 |
Ground |
Custom Power |
mdl: BCF-60125-460-3 / ser#: 8086 / year: 1995 / input = 460/3PH volts, 26 amps, 60 freq / output = 120 volts, 125 amps, DC |
|
|
1 |
Hydrogen Dryer #31 |
Batteries & Chargers |
3 |
|
Pneumatic Products Inc. |
Model No. 25HCP4-1 / Serial No. 1004620-1-2 / AC Volts – 460 / Frequency – 60 Hz / 3 Phase / 150 PSIG / Temperature - 150° F |
|
| BC-42 |
1 |
Battery Charger #42 |
Batteries & Chargers |
4 |
Ground |
Custom Power |
mdl: BCF-60125-460-3 / ser#: 8085 / year: 1995 / input = 460/3PH volts, 26 amps, 60 freq / output = 120 volts, 125 amps, DC |
|
|
1 |
Hydrogen Dryer #41 |
Batteries & Chargers |
4 |
|
Pneumatic Products Inc. |
Model No. 25HCP4-1 / Serial No. 1004620-1-1 / AC Volts – 460 / Frequency – 60 Hz / 3 Phase / 150 PSIG / Temperature - 150° F |
|
| Boiler-1 |
1 |
Combustion Engineering Steam Generator (Boiler) |
Boilers |
1 |
4 |
CE Boiler/Steam Generator |
Built 1959 / Continuous Capacity – 800,000 LB / Maximum Pressure – 1,725 PSI / Superheater - 1005° F / Reheater Capacity – 698,100 / Maximum Pressure – 575 PSI / Temperature 1005° F |
|
| Boiler-2 |
1 |
Combustion Engineering Steam Generator (Boiler) |
Boilers |
2 |
4 |
Combustion Engineering |
Compacity: 800K LB/HR / max press: 1725 PSI / 1005 deg F / Type: R / Reheater compacity: 698560 / max press: 575 / year: 1962 / MFRs#: 19645 |
|
| Boiler-3 |
1 |
Radiant Boiler |
Boilers |
3 |
4 |
Babcock & Wilcox |
Built 1965 / Capacity – 1,300,000 LB/HR / Design Pressure – 2,300 PSI / Superheater - 1005° F / Boiler H.S., SQ FT – 26,075 / Reheat Pressure – 509 PSI / Reheater Temperature 1005° F |
|
| HESI |
12 |
High Energy Spark Ignitor |
Boilers |
3 |
Multiple |
Forney Corp. |
Model 312 |
|
| Boiler-4 |
1 |
Combustion Engineering Steam Generator (Boiler) |
Boilers |
4 |
4 |
CE Boiler |
Built 1971-72 / Steaming Capacity – 1,300,000 LB/HR / Maximum Pressure – 2,400 PSI / Superheater - 1000° F / Reheater Capacity – 1,140,000 LB/HR / Maximum Pressure – 580 PSI / Temperature 1005° F / MFRs#: 21038 / Type: RRP |
|
|
36 |
Flame Signature Scanners |
Boilers |
3 & 4 |
|
Forney Corp. |
Model 1000 |
|
| NOX-1 |
1 |
Combustion Tempering System Assembly |
Combustion Temp. Sys |
3 & 4 |
5 |
RJM Corporation |
no Ser# |
|
| GSE-11 |
1 |
Gland Exhaust Condensor Assbly. |
Condensers |
1 |
Mezz |
Westinghouse |
|
|
| GSE-21 |
1 |
Gland Seal Steam Condensor |
Condensers |
2 |
Mezz |
Westinghouse |
|
|
| GSC-31 |
1 |
Gland Steam Condensor |
Condensers |
3 |
Mezz |
Westinghouse? |
with one blower |
|
| MCN-31 |
1 |
MCN-31 |
Condensers |
3 |
|
Worthington |
Built 1964 / Surface area, ft2: 100,000 / Passes/waterboxes: single, divided / Hotwell Capacity, gal: 4,800 / Heat Exchange, Btu/hr: 949,170,000 (Tubes removed) |
|
| MCN-41 |
1 |
MCN-41 |
Condensers |
4 |
|
DeLaval |
Built 1973 / Surface area, ft2: 100,000 / Passes/waterboxes: single, divided / Hotwell Capacity, gal: 8,500 / Heat Exchange, Btu/hr: 983,000,000 (Tubes removed) |
|
|
1 |
Unit 1-4 Danalyzer 2350 Gas Chromatograph |
Control Systems |
1 |
|
Daniel Industries |
Manufactured 1992 / Model 1-0520-001 / Analysis Time – 225 seconds / Cycle Time – 240 seconds / Detector Temperature - 80° ± 3° F / Carrier Gas Pressure – 85 psig (Transferred to Decker) |
|
|
1 |
Main Steam Turbine Control System (ETSI Turbine Protection System) |
Control Systems |
4 |
|
ABB Automation Inc. ETSI Turbine & Rotating Machinery Controls |
Purchased May 1999 / Serial Number ESTI Job No. M1015 / The ESTI-specific hardware and software is coupled with the Bailey Controls DCS Multifunction Processor – based hardware |
|
|
1 |
Boiler Feed Pump Turbine Control Systems (Woodward 509 Digital Control System) |
Control Systems |
4 |
|
Woodward Governor Co. Turbomachinery Controls |
Model 509 / Serial Number System No. 8260-873 / Manual No. 89358 |
|
|
1 |
Boiler Control Systems |
Control Systems |
3 & 4 |
|
Foxboro I/A Series System |
Purchased May 1995 / I/O System Count: Approx 2,000 point system / 50/51 Series System |
|
| DFWH-13 |
2 |
Cochrane Deaerator (H-DFWH-13) Tanks |
Deaerator Tank |
1 |
4 |
Cochrane Corp. |
Shop order: 281659 / Max Press: 90 lbs |
|
| DGS-1 DGS-2 |
1 |
Plant Common Diesel Generator Set #1 & 2 (DGS-1 and DGS-2) |
Diesel Generator |
1, 2, 3 & 4 |
Ground |
Caterpillar Tractor Co. |
Received 1981 / Model 3412-PC, Type: Turbo charged, after cooled / Serial No. 58BH5009 / Frame – 588 / Speed – 1,800 RPM // Ser# for DGS-1 = 58BH5207 (To be transferred to Decker) |
|
| BVF-11 |
1 |
Basement Vent Fan #11 |
Fans |
1 |
Mezz |
Joy Manufacturing Co. |
Unit No: X804-128 / MTR#: EP148-50 / Ser#: SI8680 / Volts: 220-440 / Phase: 3 / Cyc: 60 / Current: AC / 50 HP / 1150 RPM |
|
| BVF-12 |
1 |
Basement Vent Fan #12 |
Fans |
1 |
Mezz |
Joy Manufacturing Co. |
Unit No: X804-128 / MTR#: EP148-50 / Ser#: SE8680 / Volts: 220-440 / Phase: 3 / Cyc: 60 / Current: AC / 50 HP / 1150 RPM |
|
| FDF-11 |
1 |
Forced Draft Fan #11 (FDF-11) |
Fans |
1 |
6 |
Westinghouse Electric Corp., Sturtevant Division |
Model 4060-D Airfoil, Housing DIDW / Serial No. NYY 8478-1 / RPM – 1,180 / Voltage – 2,300 / HP - 600 |
|
| FDF-12 |
1 |
Forced Draft Fan #12 (FDF-12) |
Fans |
1 |
6 |
Westinghouse Electric Corp., Sturtevant Division |
Model 4060-D Airfoil, Housing DIDW / Serial No. NYY 8478-2 / RPM – 1,180 / Voltage – 2,300 / HP - 600 |
|
| SCAF-11 |
1 |
Scanner Fan #11 |
Fans |
1 |
4 |
Lincoln (motor); Maxon (fan) |
Serial No. F4192 / Motor: Voltage – 230/460 / Amps. – 12.4/6.2 / RPM – 3486 / Hertz – 60 / HP - 5 |
|
| SCAF-12 |
1 |
Scanner Fan #12 |
Fans |
1 |
4 |
Lincoln (motor); Maxon (fan) |
Serial No. F4192 / Motor: Voltage – 230/460 / Amps. – 12.4/6.2 / RPM – 3485 / Hertz – 60 / HP - 5 |
|
| FDF-21 |
1 |
Forced Draft Fan #21 (FDF-21) |
Fans |
2 |
6 |
Westinghouse Electric Corp., Sturtevant Division |
Purchased 1962 / Model 4060-D Airfoil, Housing DIDW / Ser#: S-66P788 / RPM – 1,191 / Voltage – 2,300 / HP - 600 |
|
| FDF-22 |
1 |
Forced Draft Fan #22 (FDF-22) |
Fans |
2 |
6 |
Westinghouse Electric Corp., Sturtevant Division |
Purchased 1962 / Model 4060-D Airfoil, Housing DIDW / Ser#: S-66P787 / RPM – 1,191 / Voltage – 2,300 / HP - 600 |
|
| SF-21 |
1 |
Scanner Fan #21 |
Fans |
2 |
4 |
Lincoln (motor); Maxon (fan) |
Serial No. F4192 / Motor: Voltage – 230/460 / Amps. – 12.4/6.2 / RPM – 3485 / Hertz – 60 / HP - 5 / ser#: 3081945 |
|
| SF-22 |
1 |
Scanner Fan #22 |
Fans |
2 |
4 |
Lincoln (motor); Maxon (fan) |
Serial No. F4192 / Motor: Voltage – 230/460 / Amps. – 12.4/6.2 / RPM – 3485 / Hertz – 60 / HP - 5 / ser#: 3039366 |
|
| FDF-31 |
1 |
Forced Draft Fan #31 (FDF-31) |
Fans |
3 |
8 |
Westinghouse Electric Corp., Sturtevant Division |
Purchased 1965 / Model 4073-C-D Airfoil, DWD1 Housing Type Style HUY-6354-1 / Ser#: 1S-70P37 / RPM – 1,181 / Voltage – 2,400 / HP – 1,250 / Frame No. – W3B |
|
| FDF-31 |
1 |
Forced Draft Fan #32 (FDF-32) |
Fans |
3 |
8 |
Westinghouse Electric Corp., Sturtevant Division |
Purchased 1965 / Model 4073-C-D Airfoil, DWD1 Housing Type Style HUY-6354-2 / Ser#: 2S-70P37 / RPM – 1,181 / Voltage – 2,400 / HP – 1,250 / Frame No. – W3B |
|
| SF-31 |
1 |
Scanner Fan #31 |
Fans |
3 |
6 |
Baldor (motor); New York Blower Co. (fan) |
Serial No. F0211062593 / Motor: Voltage – 230/460 / Amps. – 11.4/5.7 / Hertz – 60 / HP - 5 |
|
| SF-32 |
1 |
Scanner Fan #32 |
Fans |
3 |
6 |
WEG (motor); New York Blower Co. (fan) |
Serial No. F0211062593 / Motor: Voltage – 230/460 / Amps. – 13/7.44 / Hertz – 60 / HP – 5 |
|
| FDF-41 |
1 |
Forced Draft Fan #41 (FDF-41) |
Fans |
4 |
6 |
Westinghouse Electric Corp., Sturtevant Division |
Model 2385 DWD1/3-AF / Type: double-inlet, airfoil / RPM – 1,182 / Voltage – 2,300 / HP – 1,500 / Frame No. – W3B50 / ser#: S81P90 |
|
| FDF-42 |
1 |
Forced Draft Fan #42 (FDF-42) |
Fans |
4 |
6 |
Westinghouse Electric Corp., Sturtevant Division |
Model 2385 DWD1/3-AF / Type: double-inlet, airfoil / RPM – 1,182 / Voltage – 2,300 / HP – 1,500 / Frame No. – W3B50 / ser#: S81P90 |
|
| SF-41 |
1 |
Scanner Fan #41 |
Fans |
4 |
37347 |
GE (motor); Cincinnati (fan) |
Motor: Voltage – 230/460 / Amps. – 17.8/8.9 / Hertz – 60 / Power Factor - 90 / ser#: AKH191076008 / 7.5 HP / mdl: 5KL213BC105 // Housing = ser#: 9501869 / mdl: HP4C22 |
|
| SF-42 |
1 |
Scanner Fan #42 |
Fans |
4 |
37347 |
Toshiba (motor); Cincinnati (fan) |
Motor: Voltage – 230/460 / Amps. – 19/9.5 / RPM – 3485 / Hertz – 60 / HP - 7.5 / ser#: 020606014 / mdl: BY752FLF2UMN // Housing = ser#: 9501870 / mdl: HP4C22. |
|
| VF-41 |
1 |
Vent Fan motor assbly. |
Fans |
4 |
Mezz |
Westinghouse |
Motor = 3 phs / 60 cyc / ser#: 7210 / 125 HP / 460 volts / 142 amps |
|
| SVF-21 |
1 |
Vent Fan motor assbly. |
Fans / motors |
2 |
Mezz |
Duty Master |
ID#: 40B321-CR / 188 amps / 75 HP / 1775 RPM / 208 volts |
|
| SVF-31 |
1 |
Vent Fan motor assbly. |
Fans / motors |
3 |
Mezz |
Westinghouse |
ser#: 29N5718 / 150 HP / frame: 504-UU / mdl: ABDP / 3 phs / 60 cyc / 440 volts / 177 amps. |
|
| CF-31 |
1 |
Feedwater Heater #31 |
Feedwater Heaters |
3 |
Mezz |
Westinghouse |
Purchased 1965 / Serial No. 16-A-4811-1 / Type LP / Feedwater: Pounds per hour – 1,385,022 / Temp In – 110.8° F / Temp Out – 186.8° F / P-drop – 9.8 / Vel, fps – 5.84 / Psia – NI / Steam: Pounds per hour – 88,699 / Temp In – 191.8° F / Saturated Temp – 19 |
|
| CF-32 |
1 |
Feedwater Heater #32 |
Feedwater Heaters |
3 |
Mezz |
Westinghouse |
Purchased 1965 / Serial No. 16-A-4812-1 / Type LP / Feedwater: Pounds per hour – 1,385,022 / Temp In – 186.8° F / Temp Out – 243.3° F / P-drop – 9.8 / Vel, fps – 6.88 / Psia – NI / Steam: Pounds per hour – 70,407 / Temp In – 354.9°F / Saturated Temp – 248 |
|
| CF-35 |
1 |
Feedwater Heater #35 |
Feedwater Heaters |
3 |
Ground |
Struthers |
Purchased 1992 / Serial No. 92-06-53894 / Type HP / Feedwater: Pounds per hour – 1,515,000 / Temp In – 366.8° F / Temp Out – 412.6° F / P-drop – 9.3 / Vel, fps – 6.59 / Psia – 3,100 / Steam: Pounds per hour – 61,652 / Temp In – 840.0° F / Saturated Temp – |
|
| CF-33 |
1 |
Feedwater Heater #33 |
Feedwater Heaters |
3 |
Mezz |
Westinghouse |
Purchased 1965 / Serial No. 16-A-4813-1 / Type HP / Feedwater: Pounds per hour – 1,386,022 / Temp In – 243.3° F / Temp Out – 309.4° F / P-drop – 9.8 / Vel, fps – 7.25 / Psia – NI / Steam: Pounds per hour – 86,412 / Temp In – 547.0° F / Saturated Temp – 31 |
|
| CF-36 |
1 |
Feedwater Heater #36 |
Feedwater Heaters |
3 |
Mezz |
EFCO |
Purchased 1991 / Serial No S-23564 / Type HP / Feedwater: Pounds per hour – 1,515,000 / Temp In – 392.4° F / Temp Out – 431.4° F / P-drop – 9.3 / Vel, fps – 5.97 / Psia – 3,240 / Steam: Pounds per hour – 118,121 / Temp In – 695.8° F / Saturated Temp – 481 |
|
| CF-41 |
1 |
Feedwater Heater #41 |
Feedwater Heaters |
4 |
Mezz |
Southwestern |
Built 1973 / Serial No. 27204 / Type LP / Feedwater: Pounds per hour – 1,194,856 / Temp In – 109.6° F / Temp Out – 165.2° F / P-drop – 10.3 / Vel, fps – 6.16 / Psia – 300 / Steam: Pounds per hour –56,889 / Temp In – 173.2° F / Saturated Temp – 170.2° F / |
|
| CF-42 |
1 |
Feedwater Heater #42 |
Feedwater Heaters |
4 |
Mezz |
Southwestern |
Built 1973 / Serial No. 27205 / Type LP / Feedwater: Pounds per hour – 1,194,856 / Temp In – 165.2° F / Temp Out – 207.2° F / P-drop – 16.3 / Vel, fps – 8.49 / Psia – 300 / Steam: Pounds per hour – 45,179 / Temp In – 281.4° F / Saturated Temp – 212.2° F / |
|
| CF-43 |
1 |
Feedwater Heater #43 |
Feedwater Heaters |
4 |
Ground |
Southwestern |
Built 1973 / Serial No. 27206 / Type LP / Feedwater: Pounds per hour – 1,194,856 / Temp In – 207.2° F / Temp Out – 276.8° F / P-drop – 15.4 / Vel, fps – 8.26 / Psia – 300 / Steam: Pounds per hour – 76,622 / Temp In – 501.8° F / Saturated Temp – 281.8° F / |
|
| CF-45 |
1 |
Feedwater Heater #45 |
Feedwater Heaters |
4 |
Ground |
Kruger |
Built 1983 / Serial No. 83-121 / Type IP / Feedwater: Pounds per hour – 1,447,233 / Temp In – 322.0° F / Temp Out – 361.0° F / P-drop – NI / Vel, fps – 7.90 / Psia – 300 / Steam: Pounds per hour – 52,400 / Temp In – 765.0° F / Saturated Temp – 364.5° F / |
|
| CF-46 |
1 |
Feedwater Heater #46 |
Feedwater Heaters |
4 |
Ground |
Struthers |
Built 1992 / Serial No. 92-06-53895 / Type HP / Feedwater: Pounds per hour – 1,447,233 / Temp In – 368.4° F / Temp Out – 464.8° F / P-drop – 11.5 / Vel, fps – 6.76 / Psia – 2,400 / Steam: Pounds per hour – 151,487 / Temp In – 665.3° F / Saturated Temp – 4 |
|
| FP-11 |
1 |
Fire Sprinkler Protection Check Valve Asbly. |
Fire Protection System |
1 |
Mezz |
Fire Control Instruments |
Viking valves: MOD F-1 / 250 PSI / 16 Bar |
|
| FP-21 |
1 |
Fire Sprinkler Protection Check Valve Asbly. |
Fire Protection System |
2 |
Mezz |
Fire Control Instruments |
Viking valves: MOD F-1 / 250 PSI / 16 Bar |
|
| FP-31 |
1 |
Fire Sprinkler Protection Check Valve Asbly. |
Fire Protection System |
3 |
Mezz |
Fire Control Instruments |
Viking Valves |
|
| FP-32 |
1 |
Fire Sprinkler Protection Check Valve Asbly. |
Fire Protection System |
3 |
Mezz |
Fire Control Instruments |
Viking valves |
|
| FP-41 |
2 |
Fire Sprinkler Protection Check Valve Asbly. |
Fire Protection System |
4 |
Mezz |
Fire Control Instruments |
Viking valves |
|
|
1 |
7200 FCI Fire Control Instruments |
Fire Protection System |
1, 2, 3 & 4 |
|
Fire Control Instruments |
Primary Input Power – 120/240 VAC, 50/60 Hz, 3.0 amps / Output Power 6 amps @ 24 VC (total) / Battery Charger Capacity – 7 to 55 AH / Charge Rate – 1 or 2 amp. @ 27.1 VDC (Remote panel in Control Room #1) |
|
| GEN-11 |
1 |
Hydrogen Cooled Turbine Generator |
Generators |
1 |
Basement |
Westinghouse |
13,800 volts / Hydrogen Pressure – 30 / Kva – 133,689 / Amperes – 5,593 / Power Factor – 0.85 / Ser #: IS61P725 / Exciter Volts: 375 / Exciter Ser #: 61P726 / Exciter (H-EXC-11) |
|
| SPEXC-10 |
1 |
and Spare Exciter |
Generators |
1 |
Mezz |
Westinghouse |
300 KW / 375 Volts / 800 Amps / 1192 RPM / Instruction Book: 4700-50 / Ser#: IS62PI41 |
|
| GEN-21 |
1 |
Hydrogen Cooled Turbine Generator |
Generators |
2 |
TGB Room |
Westinghouse |
13,800 volts / Hydrogen Pressure – 30 / Kva – 133,689 / Amperes – 5,593 / Power Factor - .85 / Ser # IS66P208 / Instruction Book: 20222 // Exciter (EXC-11) Volt: 375 / Ser #: 66P206 |
|
| GEN-31 |
1 |
A.C. Generator Hydrogen Cooled – Inner Cooled with Thermastatic Stator Insulation |
Generators |
3 |
TGB Room |
Westinghouse |
1,800 volts / Hydrogen Pressure – 60 / Kva – 246,400 / Stator Amperes – 7,904 / Rotor Amperes – 2,543, |
|
| GEN-41 |
1 |
Steam Turbine Generator |
Generators |
4 |
TGB Room |
General Electric |
Water cooled Y connected for 20,000 volts / 54° C on stator Winding by Detector / Gas pressure (PSIG) – 45 / Kva – 234,000 / Stator Amperes – 6,755 / Power Factor – 0.90 / Ser#: 180X526 |
|
| H2D-11 |
1 |
H2 Dryer/Dehumidifier (H1-CTP-11) |
H2 Dryer |
1 |
Basement |
Westinghouse |
165 lbs WP / Type: AAC / Size: 25 / Ser #: 4628D7 / Volts: 110.220.208.440 / Phs 1-3 / Cyc: 60 |
|
| H2D-21 |
1 |
H2 Dryer/Dehumidifier (H2-CTP-21) |
H2 Dryer |
2 |
Basement |
Westinghouse |
165 lbs WP / Type: AAC / Size: 25 / Ser #: 8169D2 / Volts: 110.220.208.440 / Phs 1-3 / Cyc: 60 |
|
| SWC-40 |
1 |
Heat Exchanger (SWC-41) |
Heat Exchanger |
4 |
Basement |
General Electric |
ser#: 180X526 / Type: STD / class: 270-2-166 / year: 1971 |
|
| SWC-40 |
1 |
Heat Exchanger (SWC-42) |
Heat Exchanger |
4 |
Basement |
General Electric |
ser#: 2123170 / Type: STD / class: 270-2-166 / year: 1971 |
|
| HYDC-30B |
1 |
Hydraulic Oil Filter Assembly (2 filter) |
Hydraulic Oil Filter |
3 |
Mezz |
Westinghouse |
no plate visible |
|
| BFP-11 |
1 |
Boiler Feed Pump (#11 BFP Motor) |
Motors |
1 |
Basement |
Westinghouse |
Model 6-WC-13-7 / Serial No. 1S-62P511 / Amps – 264 / Horsepower – 1250 / RPM – 3557 / Volts – 2300 / Winding – 2 Pole |
Model 6-WC-13-7 / Serial No. 1S-62P511 |
| BFP-12 |
1 |
Boiler Feed Pump (#12 BFP Motor) |
Motors |
1 |
Basement |
Westinghouse |
Model 6-WC-13-7 / Serial No. 1S-62P512 / Amps – 264 / Horsepower – 1250 / RPM – 3557 / Volts – 2300 / Winding – 2 Pole |
Model 6-WC-13-7 / Serial No. 1S-62P512 |
| CWP-11 |
1 |
Circulating Water Pump (#11 CWP Motor) |
Motors |
1 |
Water Intake Area |
Westinghouse |
Serial No. 1S62P513 / Amps – 72.2 / Horsepower - 300 / RPM – 503 / Volts – 2300 / Winding – 14 / Running Torque – 3120 ft/lbs. |
|
| CWP-12 |
1 |
Circulating Water Pump (#12 CWP Motor) |
Motors |
1 |
Water Intake Area |
Westinghouse |
Serial No. 2S62P513 / Amps – 72.2 / Horsepower - 300 / RPM – 503 / Volts – 2300 / Winding – 14 / Running Torque – 3120 ft/lbs. |
|
| GSE-11 |
1 |
Gland Exhaust Condensor Assbly. - Blower |
Motors |
1 |
Mezz |
Westinghouse |
|
|
| GSE-11 |
1 |
Gland Exhaust Condensor Assbly. - Blower |
Motors |
1 |
Mezz |
Westinghouse |
|
|
| HWP-11 |
1 |
Condenser Hotwell Pump (#11 HWP Motor) |
Motors |
1 |
Basement |
Westinghouse |
Serial No. 2S-59 / Amps – 44.5 / Horsepower - 200 / RPM – 1180 / Volts – 2300 / Winding – 6 Pole / Running Torque – 890 ft/lbs |
|
| HWP-12 |
1 |
Condenser Hotwell Pump (#12 HWP Motor) |
Motors |
1 |
Basement |
Westinghouse |
Serial No. 1S-59 / Amps – 44.5 / Horsepower – 200 / RPM – 1180 / Volts – 2300 / Winding – 6 Pole / Running Torque – 890 ft/lbs |
|
| SPEXC-10 |
1 |
Spare Exciter |
Motors |
1 |
Mezz |
Westinghouse |
Model NP59949 / Serial No. 1S-62P142 / Amps – 105 / Horsepower – 450 / RPM – 1192 / Volts - 2300 |
|
| BFP-21 |
1 |
Boiler Feed Pump (#21 BFP Motor) |
Motors |
2 |
Basement |
Westinghouse |
Model 6-WC-13-7 / Serial No. 1S-62P512 / Amps – 264 / Horsepower – 1250 / RPM – 3557 / Volts – 2300 / Winding – 2 Pole |
|
| BFP-22 |
1 |
Boiler Feed Pump (#22 BFP Motor) |
Motors |
2 |
Basement |
Westinghouse |
Serial No. 1S-66P785 / Amps – 264 / Horsepower – 1250 / RPM – 3557 / Volts – 2300 / Winding – 2 Pole |
|
| CWP-21 |
1 |
Circulating Water Pump (#21 CWP Motor) |
Motors |
2 |
Water Intake Area |
Westinghouse |
Serial No. 1S66P929 / Amps – 72.2 / Horsepower - 300 / RPM – 503 / Volts – 2300 / Winding – 14 / Running Torque – 3120 ft/lbs. |
|
| CWP-22 |
1 |
Circulating Water Pump (#22 CWP Motor) |
Motors |
2 |
Water Intake Area |
Westinghouse |
Serial No. 2S-66P929 / Amps – 72.2 / Horsepower - 300 / RPM – 503 / Volts – 2300 / Winding – 14 / Running Torque – 3120 ft/lbs. |
|
| GSE-22 |
1 |
Gland Seal Steam Condensor Assbly - Turbo Blower (Exhauster 22) |
Motors |
2 |
Mezz |
Westinghouse |
Size: 2508-2 / style: ATY-4528 / ref#: R-1732-100 // Motor = Ser#: 7612 / 3460 RPM / 2 HP |
|
| GSE-21 |
1 |
Gland Seal Steam Condensor Assbly - Turbo Blower (Exhauster 21) |
Motors |
2 |
Mezz |
Westinghouse |
Size: 15051 / style: PHY-3729-1 // Motor = ser#: 24N3605-6206 / 2 HP / frame: 184. |
|
| HWP-21 |
1 |
Condenser Hotwell Pump (#21 HWP Motor) |
Motors |
2 |
Basement |
Westinghouse |
Serial No. 2S-62 / Amps – 44.5 / Horsepower - 200 / RPM – 1180 / Volts – 2300 / Winding – 6 Pole / Running Torque – 890 ft/lbs |
|
| HWP-21 |
1 |
Condenser Hotwell Pump (#22 HWP Motor) |
Motors |
2 |
Basement |
Westinghouse |
Serial No. 1S-62 / Amps – 44.5 / Horsepower - 200 / RPM – 1180 / Volts – 2300 / Winding – 6 Pole / Running Torque – 890 ft/lbs |
|
| BFP-31 |
1 |
Start-up Boiler Feed Pump (#31 BFP Motor) |
Motors |
3 |
Basement |
Westinghouse |
Model MD-302 / Serial No. 1S-69P698 / Amps – 264 / Horsepower – 1250 / RPM – 3557 / Volts – 2300 / Cycle – 60 / Phase - 3 |
|
| BFP-31 |
1 |
Start-up Boiler Feed Pump (#32 BFP Auxiliary Oil Pump Motor) (small motor) |
Motors |
3 |
Basement |
General Electric |
Model MD-302A / Serial No. 5K49HG63/G-314681 / Amps – 2.6 (1.3) / Horsepower – 0.75 / RPM – 3450 (2850) / Volts – 220 (440) / Cycle 60 / Phase - 3 |
|
| CVP-31 |
1 |
Condenser Vacuum Pump (#31 CVP Pump) |
Motors |
3 |
Basement |
Worthington |
Received 1964 / Serial No. L-78410 / Capacity – 1,012 cfm / Speed – 585 rpm / Stages – 2 / Displacement – 1342 cfm / Suction Pressure – 1” Hg Abs / Discharge Pressure – 14.7 psia |
|
| CVP-32 |
1 |
Condenser Vacuum Pump (#32 CVP Pump) |
Motors |
3 |
Basement |
Worthington |
Received 1964 / Serial No. L-78409 / Capacity – 1,012 cfm / Speed – 585 rpm / Stages – 2 / Displacement – 1342 cfm / Suction Pressure – 1” Hg Abs / Discharge Pressure – 14.7 psia |
|
| CWP-31 |
1 |
Circulating Water Pump (#31 CWP Motor) |
Motors |
3 |
Water Intake Area |
Westinghouse |
Model MD-306 / Serial No. 2S-69P566 / Amps – 125 / Horsepower - 500 / RPM – 354 / Volts – 2300 / Cycle – 60 / Phase - 3 |
|
| CWP-32 |
1 |
Circulating Water Pump (#32 CWP Motor) |
Motors |
3 |
Water Intake Area |
Westinghouse |
Model MD-307 / Serial No. 1S-69P566 / Amps – 125 / Horsepower - 500 / RPM – 354 / Volts – 2300 / Cycle – 60 / Phase - 3 |
|
| GSC-31 |
1 |
Gland Steam Condensor - Turbo Blower |
Motors |
3 |
Mezz |
Westinghouse |
size: 2512-3 / style: PHY-617-1 // Motor = ser#: 189K / 3 HP / 3515 RPM / 3 phs / 60 cyc / mdl: SDBP / 480 volts / 3.9 amps |
|
| HWP-31 |
1 |
Condenser Hotwell Pump (#31 HWP Motor) |
Motors |
3 |
Basement |
Westinghouse |
Model MD-308 / Serial No. 26N2063-1-64 / Amps – 70 / Horsepower – 300 / RPM – 1185 / Volts – 2300 / Cycle – 60 / Phase - 3 |
|
| HWP-32 |
1 |
Condenser Hotwell Pump (#32 HWP Motor) |
Motors |
3 |
Basement |
Westinghouse |
Model MD-308 / Serial No. 26N2063-2S-64 / Amps – 70 / Horsepower – 300 / RPM – 1185 / Volts – 2300 / Cycle – 60 /Phase-3 |
|
| PCP-31 |
1 |
Plant Cooling Water Pump (#31 PCWP) (Motor) |
Motors |
3 |
Basement |
Westinghouse |
Model ABDP / Serial No. 26N9529 / Amps – 121 / RPM – 1775 / Volts – 460 / Cycle – 60 / Phase-3 |
|
| PCP-32 |
1 |
Plant Cooling Water Pump (#32 PCWP) (Motor) |
Motors |
3 |
Basement |
Westinghouse |
Model ABDP / Serial No. 26N9529 / Amps – 121 / RPM – 1775 / Volts – 460 / Cycle – 60 / Phase - 3 |
|
| SPEXC-30 |
1 |
Main Exciter Generator |
Motors |
3 |
Mezz |
Westinghouse |
Serial No. 1S-69P172 / Amps – 377 / Horsepower – 1650 / RPM – 714 / Volts – 2300 / Service Factor 1.25 |
|
| BFP-42 |
1 |
Main Boiler Feed Pump Turbine Drive (BFPT #42) Turning Gear Motor |
Motors |
4 |
Mezz |
General Electric |
Model 5K182BK359 / Serial No. DG / Amps – 5.2 / Horsepower – 1.5 / RPM – 1160 / Volts – 230/460 / Cycle – 60 / Phase - 3 |
|
| CWP-41 |
1 |
Circulating Water Pump (#41 CWP Motor) |
Motors |
4 |
Water Intake Area |
Westinghouse |
Model MD-404.1 / Serial No. 1S-79P992 / Amps – 112.5 / Horsepower - 450 / RPM – 394 / Volts – 2300 / Cycle – 60 / Phase - 3 |
|
| CWP-42 |
1 |
Circulating Water Pump (#42 CWP Motor) |
Motors |
4 |
Water Intake Area |
Westinghouse |
Model MD-404.2 / Serial No. 2S-79P992 / Amps – 112.5 / Horsepower - 450 / RPM – 394 / Volts – 2300 / Cycle – 60 / Phase - 3 |
|
| HWP-41 |
1 |
Condenser Hotwell Pump (#41 HWP Motor) |
Motors |
4 |
Basement |
Westinghouse |
Model MD-404.3 / Serial No. 70F57908-1S-71 / Amps – 57 / Horsepower – 250 / RPM – 1768 / Volts – 2300 / Cycle – 60 / Phase - 3 |
|
| HWP-42 |
1 |
Condenser Hotwell Pump (#42 HWP Motor) |
Motors |
4 |
Basement |
Westinghouse |
Model MD-404.4 / Serial No. 70F57908-2S-71 / Amps – 57 / Horsepower – 250 / RPM – 1768 / Volts – 2300 / Cycle – 60 / Phase - 3 |
|
| PCP-41 |
1 |
Plant Cooling Water Pump (#41 PCP Motor) |
Motors |
4 |
Water Intake Area |
Westinghouse |
Model MD-408.4 / Serial No. 71C17264-7109 / Amps – 110 / Horsepower - 100 / RPM – 1780 / Volts – 460 / Cycle – 60 / Phase - 3 |
|
| PCP-42 |
1 |
Plant Cooling Water Pump (#42 PCP Motor) |
Motors |
4 |
Water Intake Area |
Westinghouse |
Model MD-408.5 / Serial No. 71C17264-7109 / Amps – 110 / Horsepower - 100 / RPM – 1780 / Volts – 460 / Cycle – 60 / Phase - 3 |
|
| TLOR-41 |
1 |
Turbine Lube Oil Resevoir Assembly - Blower motor assembly |
Motors |
4 |
Mezz |
RAI |
ser#: 9908106226 / mdl: 36URAI / with 1 HP motor |
|
| FSP-41 |
1 |
Fuel Service Pump, H4-FO-FSP-41 |
Motors |
RO Bldg |
Basement |
Westinghouse |
3 phase, 1175 RPM, 60 HP, 230/460 volts, 140/70 amps, ser#: 7403 |
|
| FSP-42 |
1 |
Fuel Service Pump, H4-FO-FSP-42 |
Motors |
RO Bldg |
Basement |
Westinghouse |
3 phase, 1175 RPM, 60 HP, 230/460 volts, 140/70 amps, ser#: 7402 |
|
| FSP-43 |
1 |
Fuel Service Pump, H4-FO-FSP-43 |
Motors |
RO Bldg |
Basement |
Westinghouse |
3 phase, 1175 RPM, 60 HP, 230/460 volts, 140/70 amps, ser#: 7402 |
|
| SMP-46 |
1 |
Sump Pump, H4-SMP-46 |
Motors |
RO Bldg |
Basement |
Reliance |
MTR = ser#: 1MA461982-01-AZ, 230/460 volts, 22/11 amps, 7.5 HP, 870 RPM |
|
| TLOR-11 |
1 |
Turbine Lube Oil Cooler Assbly - Turbine Lube Oil Cooler (TLOC-11) |
Oil Cooler |
1 |
Mezz |
Westinghouse |
Ser#: 16A1962-1 / size: 980 / max water press: 125 lb/in2 / Instr Bk: 1250-C497. |
|
| TLOR-11 |
1 |
Turbine Lube Oil Cooler Assbly - Turbine Lube Oil Cooler (TLOC-12) |
Oil Cooler |
1 |
Mezz |
Westinghouse |
Ser#: 16A1962-2 / size: 980 / max water press: 125 lb/in2 / Instr Bk: 1250-C497. |
|
| TLOR-21 |
1 |
Turbine Lube Oil Cooler Assbly - Turbine Lube Oil Cooler (TLOC-21) |
Oil Cooler |
2 |
Mezz |
Westinghouse |
ser#: 16A3463-2 / size: 980 / max water press: 125 / instr. Bk: 1250C-554 |
|
| TLOR-21 |
1 |
Turbine Lube Oil Cooler Assbly - Turbine Lube Oil Cooler (TLOC-22) |
Oil Cooler |
2 |
Mezz |
Westinghouse |
ser#: 16A3463-1 / size: 980 / max water press: 125 / instr. Bk: 1250C-554 |
|
| TLOR-31 |
1 |
Turbine Lube Oil Resevoir Assembly - Turbine Lube Oil Cooler (TLOC-32) |
Oil Cooler |
3 |
Mezz |
Westinghouse |
Ser#: 16A4423-2 / Size: 980 ft2 / Inst. Bk: 1250C605 |
|
| TLOR-31 |
1 |
Turbine Lube Oil Resevoir Assembly - Turbine Lube Oil Cooler (TLOC-31) |
Oil Cooler |
3 |
Mezz |
Westinghouse |
Ser#: 16A4423-1 / Size: 980 ft2 / Inst. Bk: 1250C605 |
|
| TLOR-41 |
1 |
Turbine Lube Oil Resevoir Assembly - Turbine Lube Oil Cooler (TLOC-43) |
Oil Cooler |
4 |
Mezz |
General Electric |
ser#: 223190 / S/O: 186G713H / No: 943D946 P-1 / type: S-F |
|
| TLOR-41 |
1 |
Turbine Lube Oil Resevoir Assembly - Turbine Lube Oil Cooler (TLOC-42) |
Oil Cooler |
4 |
Mezz |
General Electric |
ser#: 223191 / S/O: 186G713H / No: 943D946 P-1 / type: S-F |
|
| TLOR-41 |
1 |
Turbine Lube Oil Resevoir Assembly - Turbine Lube Oil Cooler (TLOC-41) |
Oil Cooler |
4 |
Mezz |
General Electric |
ser#: 223192 / S/O: 186G713H / No: 943D946 P-1 / type: S-F |
|
| OWS-01 |
1 |
Oil Water Seperator |
Oil Water Seperator |
Oil Water Seperator |
Outside |
|
Oil Water Seperator Unit |
|
| OC-31 |
1 |
Turbine Generator Building |
Overhead Cranes |
3 |
TGB Room |
Reliable Crane Inc. |
Serial No. 22650GCH86 / Capacity – 10 ton / Portable Crane / Auto Operated / Located – Turbine Floor |
|
| GC-43 |
|
(Truck Bay) Gantry Crane (GC-43) |
Overhead Cranes |
4 |
TGB Room |
Kranco, Inc. |
Installed 1981 / Serial No. LJ-1158 / Capacity – 6 tons / Manually Operated / Located – Holly 4 West Truck Bay |
|
| GCBD-41 |
1 |
Gantry Crane |
Overhead Cranes |
4 |
TGB Room |
Wright Hoist Div. |
Serial No. 1-71-13708-1 / Model – B-669 / Capacity – 7.5 tons / Auto Operated / Located – Holly 4 Main Boiler Feed Pump |
|
| OC-11 |
1 |
Overhead Crane: Bridge Drive (OCBD-11), Trolley Drive (OCTD-11), Auxillary Hoist (OCAH-11), Main Hoist (OCMH-11) |
Overhead Cranes |
1, 2, 3 & 4 |
TGB Room |
Whiting Cranes |
Serial No. 8227 / Capacity – 100 ton/15 ton / Auto Operated / Located – Turbine floor |
|
| GC-42 |
1 |
Auxiliary Boiler House (RO) Gantry Crane (GC-42) |
Overhead Cranes |
N/A |
Basement |
Stewart |
Serial No. B-1215 (bridge) / Model – Series 1000 / Capacity – 1.5 tons / Manually Operated / Located – RO Building |
|
|
1 |
Maintenance Building Gantry Crane (GC-21) |
Overhead Cranes |
N/A |
|
Lypta Cranes, Inc. |
Received 1962 / Serial No. LJ-1877 / Model UHE-S / Capacity – 7.5 tons / Auto Operated / Located – Maintenance Bldg. |
|
| CFP-31 |
1 |
Chemical Feed Pump |
Pump |
3 |
Mezz |
Lapp Pulsafeeder |
ser#: X-3871 / mdl: CPS-4 / stroke: 3.2" / piston: 1/2" |
|
| BFP-42 |
1 |
Boiler Feed Pump Assembly - Auxillary Pump? |
Pump |
4 |
Mezz |
FALK |
mdl: 5051YOA / 400HP / 5600 Input RPM / 1600 output RPM |
|
| VEP-21 |
1 |
Turbine Oil Reserve Pump |
Pump |
4 |
Mezz |
General Electric |
Motor = mdl: 5K14BK316 / 3/4 HP / 460 volts / 3.1 amps // Pump = ser#: 6100427 / size: 36 / type: AF |
|
| SMP-13 |
1 |
Sump Pump |
Pump / Motor |
1 |
Water Intake Area |
General Electric |
1745 RPM / ser#: 5K213DP5008 / 460 volts / 13 amps |
|
| SWP-11 |
1 |
Screen Wash Pump |
Pump / Motor |
1 |
Water Intake Area |
Westinghouse |
cant read tag |
|
| SWP-12 |
1 |
Screen Wash Pump |
Pump / Motor |
1 |
Water Intake Area |
Westinghouse |
40 HP / ser#: 23N3456 / 1765 RPM / 440 volts |
|
| SWP-21 |
1 |
Screen Wash Pump |
Pump / Motor |
2 |
Water Intake Area |
Westinghouse |
Motor = 40 HP / 23N3456 / mdl: ABFC // Pump = ser#: H-388603 / 470 volts / 1750 RPM |
|
| SWP-22 |
1 |
Screen Wash Pump |
Pump / Motor |
2 |
Water Intake Area |
Westinghouse |
Motor = 40 HP / 23N3456 / mdl: ABFC // Pump = ser#: 84-1D417 / size: 10 / type: DOH |
|
| HYDC-30A |
1 |
Hydraulic Pump Assembly - HDLOP-32 |
Pump / Motor |
3 |
Mezz |
Westinghouse |
Motor = 20 HP / ser#: 474B861G67 / 1755 RPM / 52-50 amps / 440 volts // Pumps = ser#: 235040 / type: 3DB312 |
|
| HYDC-30A |
1 |
Hydraulic Pump Assembly - AHDLOP-31 |
Pump / Motor |
3 |
Mezz |
Westinghouse |
Motor = 1750 RPM / ser#: 1S-64 / style: 27N2189 / 5 HP / 36 amps / 125 volts // Pump = ser#: 3DB187 / type: 27081 |
|
| HYDC-30A |
1 |
Hydraulic Pump Assembly - HDLOP-31 |
Pump / Motor |
3 |
Mezz |
Westinghouse |
Motor = 20 HP / ser#: 474B861G67-6411 / 1755 RPM / 52-50 amps / 440 volts // Pumps = ser#: 235041 / type: 3DB312 |
|
| SMP-33 |
1 |
Sump Pump |
Pump / Motor |
3 |
Water Intake Area |
Westinghouse |
Motor = ser#: 28N3005 / 440 volts / 4.4 amps / 3 HP / 1725 RPM |
|
| TLOR-31 |
1 |
Turbine Lube Oil Resevoir Assembly - Auxillary Turbine Oil Pump (ATOP-31) |
Pump / Motor |
3 |
Mezz |
Westinghouse |
25 HP / 3570 RPM / ser#: 1S-64 |
|
| TLOR-31 |
1 |
Turbine Lube Oil Resevoir Assembly - Turning Gear Oil Pump (TGOP-31) |
Pump / Motor |
3 |
Mezz |
Westinghouse |
15 HP / mdl: ABEP / 480 volts / 17 amps / 1750 RPM / ser#: 27N8415 |
|
| TLOR-31 |
1 |
Turbine Lube Oil Resevoir Assembly - Emergency Bearing Oil Pump (EBOP-31) |
Pump / Motor |
3 |
Mezz |
Westinghouse |
1800 RPM / 15 HP / 108 amps / ser#: 1S-64 / sytle: 27N7708 / explosion resistant. |
|
| TLOR-31 |
1 |
Turbine Lube Oil Cooler Assbly - Oil Vapor Extraction Resevoir pump (VEP-31) |
Pump / Motor |
3 |
Mezz |
Westinghouse |
2HP / mdl: ABNV / 2.75 amps / 480 volts / 1155 RPM / ser#: 27N3034 |
|
| BFP-42 |
1 |
Boiler Feed Pump Assembly - BFPTLOP-44 |
Pump / Motor |
4 |
Mezz |
General Electric |
50 HP / 3545 RPM / 460 volts / 60.5 amps / ser#: EG6194016 |
|
| BFP-42 |
1 |
Boiler Feed Pump Assembly - BFPTLOP-43 |
Pump / Motor |
4 |
Mezz |
General Electric |
50 HP / 3545 RPM / 460 volts / 60.5 amps / ser#: EG6194017 |
|
| BFP-42 |
1 |
Boiler Feed Pump Assembly - BFPTLOP-42 |
Pump / Motor |
4 |
Mezz |
General Electric |
7.5 HP / ser#: HG-1-253 / 52 amps / 125 volts / 3500 RPM |
|
| CTP-41 |
1 |
Condensate Drain Tank Pump (CS-CTP-41) |
Pump / Motor |
4 |
Basement |
Westinghouse |
ser#: 6909 / 1760 RPM / 3 HP / connected to tank CDT-41) |
|
| GSE-41 |
1 |
Gland Steam Exhauster |
Pump / Motor |
4 |
Basement |
Westinghouse |
ser#: 850665 / 5HP // Motor = 5HP / 460 volts / 5.7 amps / 3480 RPM |
|
| GSE-42 |
1 |
Gland Steam Exhauster |
Pump / Motor |
4 |
Basement |
Westinghouse |
ser#: 900976 / 5HP // Motor = ser#: 00536EPSE1841 / 5HP / 460 volts / 5.7 amps / 3480 RPM |
|
| LTP-41 |
1 |
Pump and Motor |
Pump / Motor |
4 |
Sub-Basement |
WEG |
mdl: 00518XP3E184T / 460 volts / 13.8 amps / 1745 RPM / 5 HP / 3 phs |
|
| RO-P-11 |
1 |
Screen Wash Pump |
Pump / Motor |
4 |
Water Intake Area |
Baldor |
Cat#: VM4108T / spec#: 10E3 10X187HI / 3520 RPM / 30HP / 460 volts / 70 amps / phase 3 / 60 cycles |
|
| RO-P-8 |
1 |
Lake Water Supply Pump |
Pump / Motor |
4 |
Water Intake Area |
US Electrical Motors |
Cat# HT2052BLE / mdl: 7022 / 20 HP / 1760 RPM / 460 volts / 52.4 amps |
|
| SMP-41 |
1 |
Sump Pump - Verticle |
Pump / Motor |
4 |
Sub-Basement |
Worthington |
ser#: 7304 / 460 volts / 8.2 amps / 1755 RPM // Pump = ser#: 9S072172 / size: 6H18-1 |
|
| SMP-43 |
1 |
Sump Pump |
Pump / Motor |
4 |
Water Intake Area |
Westinghouse |
Motor = 3 HP / ser#: 7304 / 1755 RPM // Pump = type: VTR / size: BMQL-35T / ser#: 00KN0510 |
|
| SMP-44 |
1 |
Sump Pump |
Pump / Motor |
4 |
Sub-Basement |
Reliance / Ingersoll Rand |
Motor = ser#: P14G2402N-GX / 1.5 HP / 1780 RPM / 460 volts / 5.6 amps // Pump = ser#: 0596B230B TD / 3 GAU |
|
| SMP-45 |
1 |
Sump Pump |
Pump / Motor |
4 |
Basement |
Westinghouse |
Motor = 15 HP / ser#: 7301 / 1755 RPM / 460 volts / 19.5 amps |
|
| SWP-41 |
1 |
Screen Wash Pump |
Pump / Motor |
4 |
Water Intake Area |
Westinghouse |
Ser#: 7109 / 75 HP / 1775 RPM / Frame: 404TP / mdl: TBFC / 460 volts / 85 amps // Pump = ser#: VTP-31974 / size: 12H110-4 |
|
| SWP-42 |
1 |
Screen Wash Pump |
Pump / Motor |
4 |
Water Intake Area |
Westinghouse |
Ser#: 7109 / 75 HP / 1775 RPM / Frame: 404TP / mdl: TBFC / 460 volts / 85 amps // Pump = ser#: VTP-31975 / size: 12H110-4 |
|
| TOC-41 |
1 |
Turbine Oil Centrifuge Unit |
Pump / Motor |
4 |
Sub-Basement |
DeLaval / Louis Allis |
Pump = mdl: 35-25 / ser: 3521695 // Motor = 2 HP / 1740 RPM / 440 volts / 6/3 amps / ser#: 2034161 |
|
| HOPO-1 |
1 |
Oil Water Seperator Pump |
Pump / Motor |
Oil Water Seperator |
Outside |
Gorman Pump / Westinghouse |
Self Priming Centrifigal Pump = Ser# 1211909, mdl: T6A60-B, diam: STD // MTR = 1745 RPM, 5 HP |
|
| HOPO-2 |
1 |
Oil Water Seperator Pump |
Pump / Motor |
Oil Water Seperator |
Outside |
Gorman Pump / Westinghouse |
Self Priming Centrifigal Pump = Ser# 1213834, mdl: T6A60-B, diam: STD // MTR = 1745 RPM, 5 HP |
|
| HOPO-4 |
1 |
Oil Water Seperator Pump |
Pump / Motor |
Oil Water Seperator |
Outside |
Viking Pump / GE Motor |
Pump = C30S, ser#: WM900148/A/01 // MTR = 3 HP, 3.9 A, 3 phase |
|
| BFP-11 |
1 |
Boiler Feed Pump (#11 BFP Pump) |
Pumps |
1 |
Basement |
Worthington |
Received 1959 / Model 6-WC-13-7 / Serial No. 1583035 / Capacity – 990 gpm / Speed – 3,562 rpm / Stages – 7 / Efficiency – 76% / Total Head – 4,483 ft. / Suction Pressure – 88 psig / Discharge Pressure – 1,860 psig |
Model 6-WC-13-7 / Serial No. 1583035 |
| BFP-12 |
1 |
Boiler Feed Pump (#12 BFP Pump) |
Pumps |
1 |
Basement |
Worthington |
Received 1959 / Model 6-WC-13-7 / Serial No. 1583036 / Capacity – 990 gpm / Speed – 3,562 rpm / Stages – 7 / Efficiency – 76% / Total Head – 4,483 ft. / Suction Pressure – 88 psig / Discharge Pressure – 1,860 psig |
|
| CFP-12 |
1 |
Chemical Feed Pump (and 2HP motor) |
Pumps |
1 |
Outside Mezz |
Lapp Insulator Co. / Westinghouse mtr |
Pump = Mdl: CPS-3 / Ser #: X-917 / Piston: 3/8" / Stroke: 2.3" / Reagent head: SS-316 / Diop: SS-316 // Motor = 1 HP / Frame: 182 / Mdl: ABNV / Ser # 319B315607 / Phase 3 |
|
| CFP-13 |
1 |
Chemical Feed Pump (and 2HP motor) |
Pumps |
1 |
Outside Mezz |
Lapp Insulator Co. / Westinghouse mtr |
Pump = Mdl: CPS-4 / Ser #: X-3870 / Piston: 5" / Stroke: 3.2" / Reagent head: SS-316 / Diop: SS-316 // Motor = 2 HP / Frame: 184 / Mdl: ABFC / Ser # 319B315G23 / Phase 3 |
|
| CWP-11 |
1 |
Circulating Water Pump (#11 CWP Pump) |
Pumps |
1 |
Water Intake Area |
Westinghouse |
Model 36MT / Serial No. 16-A-2164-2 / Capacity - 32,500 gpm / Speed – 505 rpm / Stages – 1 / Efficiency – 85% / Total Head – 30 ft. / Vertical Mount |
|
| CWP-12 |
1 |
Circulating Water Pump (#12 CWP Pump) |
Pumps |
1 |
Water Intake Area |
Westinghouse |
Model 36MT / Serial No. 16-A-2164-1 / Capacity - 32,500 gpm / Speed – 505 rpm / Stages – 1 / Efficiency – 85% / Total Head – 30 ft. / Vertical Mount |
|
| HWP-11 |
1 |
Condenser Hotwell Pump (#11 HWP Pump) |
Pumps |
1 |
Basement |
Westinghouse |
Model 85-RN / Serial No. 16-A-2165-2 / Capacity – 1,350 gpm / Speed – 1,180 rpm / Stages – 5 / Efficiency – 79% / Total Head – 425 ft. |
|
| HWP-12 |
1 |
Condenser Hotwell Pump (#12 HWP Pump) |
Pumps |
1 |
Basement |
Westinghouse |
Model 85-RN / Serial No. 16-A-2165-1 / Capacity – 1,350 gpm / Speed – 1,180 rpm / Stages – 5 / Efficiency – 79% / Total Head – 425 ft. |
|
| LTP-11 |
1 |
Turbine Lube Oil Transfer Pump |
Pumps |
1 |
Basement |
Worthington |
Ser. #: FT2829, Type: PB, 5 HP, 13.3 Amps, 6 gauge pump |
|
| PCP-11 |
1 |
#11 Plant Cooling Water Pump and Motor Assembly |
Pumps |
1 |
Basement |
Worthington |
Serial No. A 797178 / Model 8LR-12 / Group No. – AABN / Motor Frame – 326T / HP – 50 / RMP - 1760 |
|
| PCP-12 |
1 |
#12 Plant Cooling Water Pump and Motor Assembly |
Pumps |
1 |
Basement |
Worthington |
Serial No. A 797177 / Model 8LR-12 / Group No. – AABN / Motor Frame – 326T / HP – 50 / RMP – 1760 |
|
| SMP-11 |
1 |
Sump Pump Basement (#11 SMP) |
Pumps |
1 |
Basement |
Worthington |
|
|
| SMP-14 |
1 |
Sump Pump Basement (#14 SMP) |
Pumps |
1 |
Basement |
Worthington |
Serial #: GN945, Style: 303781, 3.5 HP |
|
| SMP-16 |
1 |
Sump Pump High Level |
Pumps |
1 |
Basement |
Worthington |
|
|
| TLOR-11 |
1 |
Turbine Lube Oil Cooler Assbly - Emergency Turb. Bearing Oil Pump (ETOP-11) |
Pumps |
1 |
Mezz |
Westinghouse |
Ser#: 1S-59 / 3600 RPM / 10 HP / frame: 324-P / style: 1636285 / 78 amps / 25 volts. |
|
| TLOR-11 |
1 |
Turbine Lube Oil Cooler Assbly - Turning Gear Bearing Oil Pump (TGBOP-11) |
Pumps |
1 |
Mezz |
Westinghouse |
Ser#: 16B3927 / 10 HP / 3480 RPM / 3 phase / 60 cyc / model: ABEP. |
|
| TLOR-11 |
1 |
Turbine Lube Oil Cooler Assbly - Auxilary Turbine Lube Oil Pump (ATOP-11) |
Pumps |
1 |
Mezz |
Westinghouse |
Ser#: 23N7339 / 40 HP / 3550 RPM / frame: 364UP / model: AAEP / 3 phase / 60 cyc / 440 volts / 48 amps. |
|
| TLOR-11 |
1 |
Turbine Lube Oil Cooler Assbly - Oil Vapor Extraction Resevoir pump (VEP-11) |
Pumps |
1 |
Mezz |
Westinghouse |
Ser#: 19N7978 / 2 HP / 1155 RPM / 3 phase / 60 cyc / 440 volts / 3 amps. |
|
| TOC-11 |
1 |
Turbine Lube Oil Centrifuge Pump |
Pumps |
1 |
Basement |
DeLaval |
Ser. #: 3530185, Mdl: 67-05 |
|
| BFP-21 |
1 |
Boiler Feed Pump (#21 BFP Pump) |
Pumps |
2 |
Basement |
Worthington |
Received 1963 / Model 6-WC-13-7 / Serial No. 1593810 / Capacity – 990 gpm / Speed – 3,562 rpm / Stages – 7 / Efficiency – 76% / Total Head – 4,483 ft. / Suction Pressure – 88 psig / Discharge Pressure – 1,860 psig |
|
| BFP-22 |
1 |
Boiler Feed Pump (#22 BFP Pump) |
Pumps |
2 |
Basement |
Worthington |
Received 1963 / Model 6-WC-13-7 / Serial No. 1593809 / Capacity – 990 gpm / Speed – 3,562 rpm / Stages – 7 / Efficiency – 76% / Total Head – 4,483 ft. / Suction Pressure – 88 psig / Discharge Pressure – 1,860 psig |
|
| CFP-21 |
1 |
Chemical Feed Pump |
Pumps |
2 |
Mezz |
Lapp Pulsafeeder |
Ser#: X-918 / piston: 1/2" / model: CPS-4 / stroke: 3.2" // motor: 2 HP / Ser#: 319B315G23-6201 / 1735 RPM / 3 phs / 60 cyc |
|
| CFP-22 |
1 |
Chemical Feed Pump |
Pumps |
2 |
Mezz |
Lapp Pulsafeeder |
Ser#: X-919 / piston: 1/2" / model: CPS-4 / stroke: 3.2" // motor: 2 HP / Ser#: 319B315G23-6309 / 1735 RPM / 3 phs / 60 cyc |
|
| CTP-21 |
1 |
Condensate Drain Tank Pump |
Pumps |
2 |
Basement |
Westinghouse |
Ser#: 8507 / 3 phase / 3 HP / 3475 RPM / 3.8 amps / Model: TEDP |
|
| CTP-22 |
1 |
Condensate Drain Tank Pump |
Pumps |
2 |
Basement |
Westinghouse |
Ser#: 8602 / 3 phase / 3 HP / 3515 RPM / 3.8 amps / Model: TEDP |
|
| CWP-21 |
1 |
Circulating Water Pump (#21 CWP Pump) |
Pumps |
2 |
Water Intake Area |
Westinghouse |
Received 1962 / Model 36MT / Serial No. 16-A-3572 - 1 / Capacity - 32,500 gpm / Speed – 505 rpm / Stages – 1 / Efficiency – 85% / Total Head – 30 ft. / Vertical Mount |
|
| CWP-22 |
1 |
Circulating Water Pump (#22 CWP Pump) |
Pumps |
2 |
Water Intake Area |
Westinghouse |
Received 1962 / Model 36MT / Serial No. 16-A-3572-2 / Capacity - 32,500 gpm / Speed – 505 rpm / Stages – 1 / Efficiency – 85% / Total Head – 30 ft. / Vertical Mount |
|
| HWP-21 |
1 |
Condenser Hotwell Pump (#21 HWP Pump) |
Pumps |
2 |
Basement |
Westinghouse |
Received 1962 / Model 85-RN / Serial No. 16-A-3573-1 / Capacity – 1,350 gpm / Speed – 1,180 rpm / Stages – 5 / Efficiency – 79% / Total Head – 425 ft. |
|
| HWP-22 |
1 |
Condenser Hotwell Pump (#22 HWP Pump) |
Pumps |
2 |
Basement |
Westinghouse |
Received 1962 / Model 85-RN / Serial No. 16-A-3573-2 / Capacity – 1,350 gpm / Speed – 1,180 rpm / Stages – 5 / Efficiency – 79% / Total Head – 425 ft. |
|
| LTP-21 |
1 |
Turbing Lube Oil Transfer Pump |
Pumps |
2 |
Basement |
Worthington |
Motor = Ser#: HN16408 / style: 308259 / 5 HP / 1750 RPM / 13.8/6.9 Amps / 3 phase / Type: PB // Pump = 6 Gauge 9477B |
|
| PCP-21 |
1 |
#21 Plant Cooling Water Pump and Motor Assembly |
Pumps |
2 |
Basement |
Worthington |
Serial No. A 797178 / Model 8LR-12 / Group No. – AABN / Motor Frame – 326T / HP – 50 / RMP - 1760 |
|
| PCP-22 |
1 |
#22 Plant Cooling Water Pump and Motor Assembly |
Pumps |
2 |
Basement |
Worthington |
Serial No. A 797177 / Model 8LR-12 / Group No. – AABN / Motor Frame – 326T / HP – 50 / RMP - 1760 |
|
| SMP-21 |
1 |
Sump Pump Basement |
Pumps |
2 |
Basement |
Worthington |
Ser#: VTP-982 |
|
|
1 |
Turbine Lube Oil Cooler Assbly - Emergency Turb. Bearing Oil Pump (ETOP-21) |
Pumps |
2 |
Mezz |
Westinghouse |
ser#: 1S-62 / 10 HP / 125 Volts / 78 amps / 3600 RPM / style: 23N8179. |
|
| TLOR-21 |
1 |
Turbine Lube Oil Cooler Assbly - Turning Gear Bearing Oil Pump (TGBOP-21) |
Pumps |
2 |
Mezz |
Westinghouse |
ser#: 23N7314 / 10 HP / frame: 254UP / mdl: ABEP / 3 phs / 60 cyc / 440 volts / 12.6 amps / 3480 RPM. |
|
| TLOR-21 |
1 |
Turbine Lube Oil Cooler Assbly - Auxilary Turbine Lube Oil Pump (ATOP-21) |
Pumps |
2 |
Mezz |
Westinghouse |
ser#: 16B3956 / 40 HP / 3 phs / 60 cyc / 46 amps / 440 volts / frame: 405P. |
|
| TLOR-21 |
1 |
Turbine Lube Oil Cooler Assbly - Oil Vapor Extraction Resevoir pump (VEP-21) |
Pumps |
2 |
Mezz |
Westinghouse |
ser#: 24N3220 / 2 HP / frame: 213 / mdl: ABEP / 3 phs / 60 cyc / 1155 RPM / class B / 6.3 amps. |
|
| TOC-21 |
1 |
Turbing Lube Oil Centrifuge |
Pumps |
2 |
Basement |
DeLaval / Louis Allis |
Motor = Ser#: 2256478006 / Type: FX / 2 HP / 6/3 Amps / 1740 RPM / 3 phase / 60 cycle // Pump = Model: 67-25 / Ser#: 3525768 |
|
| BFP-31 |
1 |
Start-up Boiler Feed Pump #31 (Pump) |
Pumps |
3 |
Basement |
De Laval Turbine, Inc. |
Purchased 1966 / Model 7BAX136 / Serial No. 701982 / Capacity: 90 gpm / Speed: 3,557 / Brake: 1,285 / Stages: 7 / Operating Temperature: 314° F / Total Head: 4,500 ft. NO Name Plate! |
|
| CTP-31 |
1 |
Condensate Drain Tank Pump |
Pumps |
3 |
Basement |
Worthington |
Motor = ser#: 28N8003 / 2 HP / 1740 RPM. |
|
| CTP-32 |
1 |
Condensate Drain Tank Pump |
Pumps |
3 |
Basement |
Worthington |
Motor = ser#: DX172147 / mdl: 5K213DP6011 / 3 HP / 1750 // Pump = ser#: 6583 / size: 55/80DB0-2 |
|
| CVP-31 |
1 |
Condenser Vacuum Pump (#31 CVP Pump) |
Pumps |
3 |
Basement |
Worthington |
Received 1964 / Serial No. L-78410 / Capacity – 1,012 cfm / Speed – 585 rpm / Stages – 2 / Displacement – 1342 cfm / Suction Pressure – 1” Hg Abs / Discharge Pressure – 14.7 psia |
|
| CVP-32 |
1 |
Condenser Vacuum Pump (#32 CVP Pump) |
Pumps |
3 |
Basement |
Worthington |
Received 1964 / Serial No. L-78409 / Capacity – 1,012 cfm / Speed – 585 rpm / Stages – 2 / Displacement – 1342 cfm / Suction Pressure – 1” Hg Abs / Discharge Pressure – 14.7 psia |
|
| CWP-31 |
1 |
Circulating Water Pump (#31 CWP Pump) |
Pumps |
3 |
Water Intake Area |
Ingersoll-Rand |
Received 1965 / Serial No. 0364-222 / Capacity - 69,500 gpm / Speed – 350 rpm / Stages – 1 / Efficiency – 88% / Total Head – 23 ft. / Vertical Mount |
|
| CWP-32 |
1 |
Circulating Water Pump (#32 CWP Pump) |
Pumps |
3 |
Water Intake Area |
Ingersoll-Rand |
Received 1965 / Serial No. 0365-221 / Capacity - 69,500 gpm / Speed – 350 rpm / Stages – 1 / Efficiency – 88% / Total Head – 23 ft. / Vertical Mount |
|
| GEN-31 |
1 |
Main Boiler Feed Pump Turbine Shaft Driven (#31 BFP Pump) |
Pumps |
3 |
TGB Room |
De Laval |
Received 1966 / Model 6BB21310 / Serial No. 701981 / Capacity – 3,238 gpm / Speed – 3,430-3,600 rpm / Stages – 6 / Efficiency – 86.6% / Total Head – 5,400 ft. / Suction Pressure – 181 psig / Discharge Pressure – 2,250 psig |
|
| GEN-31 |
1 |
Main Boiler Feed Pump Fluid Drive Coupling (FCD #31) |
Pumps |
3 |
TGB Room |
De Laval (American-Standard) |
Received 1966 / Model Gyrol Class 7, Size 212 / Serial No. 79-212-7-25 / Driven Speed – 3,600 rpm / Max. Horsepower – 6,400 / Cooling Water Supply – 340 gpm |
|
| HDP-35 |
1 |
Heater Drain Pump |
Pumps |
3 |
Basement |
Worthington |
Pump = Ser#: 1602385 / 2HNB113 / 1750 RPM / 160 GPM // Motor = ser#: BB53145 / 1765 RPM / 10 HP. |
|
| HWP-31 |
1 |
Condenser Hotwell Pump (#31 HWP Pump) |
Pumps |
3 |
Mezz |
Worthington |
Received 1964 / Model 15M-185-15 / Serial No. VTP-11165 / Capacity – 1,300 gpm / Speed – 1,180 rpm / Stages – 15 / Efficiency – 84% / Total Head – 700 ft. |
|
| HWP-32 |
1 |
Condenser Hotwell Pump (#32 HWP Pump) |
Pumps |
3 |
Mezz |
Worthington |
Received 1964 / Model 15M-185-15 / Serial No. VTP-11166 / Capacity – 1,300 gpm / Speed – 1,180 rpm / Stages – 15 / Efficiency – 84% / Total Head – 700 ft. |
|
| LTP-31 |
1 |
Turbine Lube Oil Transfer Pump |
Pumps |
3 |
Mezz |
Worthington |
Motor = ID#: P21E596P / 1755 RPM / 13.6-6.8 Amps / 60 cyc / frame: 215Y // Pump = 6 GAFT |
|
| PCP-31 |
1 |
Plant Cooling Water Pump (#31 PCWP) (Pump) |
Pumps |
3 |
Basement |
ITT |
Rebuilt 1994 / Serial No. 1-28009-01-2 / Model 100 / Capacity – 3,000 gpm / Speed – 1700 rpm / Max. Hydrotest Pressure - 175 |
|
| PCP-32 |
1 |
Plant Cooling Water Pump (#32 PCWP) (Pump) |
Pumps |
3 |
Basement |
ITT |
Rebuilt 1994 / Serial No. 1-28009-01-1 / Model 100 / Capacity – 3,000 gpm / Speed – 1700 rpm / Max. Hydrotest Pressure - 175 |
|
| SMP-34 |
1 |
Sump Pump |
Pumps |
3 |
Basement |
Worthington |
1145 RPM / 1.5 HP / type: P / frame: 184Y |
|
| SMP-35 |
1 |
Sump Pump |
Pumps |
3 |
Basement |
Worthington |
Motor = 15 HP / Ser#: 3498993 / 1730 RPM / 38/19 Amps / 60 Cyc / Model: ADBP / Frame: 2560PH // Pump = Ser#: UTP 12229 / size: 10 HH-110-2 |
|
| SOU-31 |
1 |
Seal Oil Unit Assembly - Emergency Seal Oil Pump (ESOP-31) |
Pumps |
3 |
Basement |
Worthington |
Ser#: 306B337L01 / 5 HP / 1150 RPM / Ser#2: 5K256AN379B |
|
| SOU-31 |
1 |
Seal Oil Unit Assembly - Auxilary Seal Oil Pump (ASOP-31) |
Pumps |
3 |
Basement |
Worthington |
no plate visible |
|
| TOC-31 |
1 |
Turbine Lube Oil Centrifuge Pump |
Pumps |
3 |
Basement |
DeLaval / Louis Allis |
Pump = Model: 67-25 / Ser#: 3526623 // Motor = model: 15807 / frame: 184 / 1735 RPM / 3 phase / 60 cycle. |
|
| BFP-42 |
1 |
Main Boiler Feed Pump (#42 BFP Pump) |
Pumps |
4 |
Mezz |
Allis-Chalmers |
Received 1972 / Model 10 x 10 HPTX 32-4 / Serial No. 832-6000-1 / Capacity: 3,440 gpm / Speed: 5,600 rpm / Stages: 4 / Efficiency: 80% / Total Head: 5,980 ft. / Suction Pressure – 230 psig / Discharge Pressure: 2,526 psig |
|
| BFP-42 |
1 |
Main Boiler Feed Pump Steam Turbine Drive (BFPT #42) |
Pumps |
4 |
Mezz |
General Electric |
Received 1972 / Model DRV-631 / Serial No. 122782 / Driven Speed – 5,600 rpm / HP – 6,150 / Stages 6 / Exhaust Pressure – 3” Hg Abs. / HP Stop Valve: Inlet Steam Pressure – 1,985 psig / Inlet Steam Temperature - 1000° F / LP Stop Valve: Inlet Steam Pressu |
|
| CVP-41 |
1 |
Unit #41 Vacuum Pump |
Pumps |
4 |
Basement |
Siemens |
Purchased 1987 / Serial No. 525124 / Model 118 / Type: 2BE1253-0MY47 / with 75 HP motor |
|
| CVP-42 |
1 |
Unit #42 Vacuum Pump |
Pumps |
4 |
Basement |
Siemens |
Purchased 1987 / Serial No. 525125 / Model 118 / Type: 2BE1253-0MY47 / with 75 HP motor |
|
| CWP-41 |
1 |
Circulating Water Pump (#41 CWP Pump) |
Pumps |
4 |
Water Intake Area |
Worthington |
Model 60-KLD-60 / Serial No. VTP-31023 / Capacity – 85,000 gpm / Speed – 395 rpm / Stages – 1 / Efficiency – 77.2% / Total Head – 12 ft. |
|
| CWP-42 |
1 |
Circulating Water Pump (#42 CWP Pump) |
Pumps |
4 |
Water Intake Area |
Worthington |
Model 60-KLD-60 / Serial No. VTP-31024 / Capacity – 85,000 gpm / Speed – 395 rpm / Stages – 1 / Efficiency – 77.2% / Total Head – 12 ft. |
|
| HWP-41 |
1 |
Condenser Hotwell Pump (#41 HWP Pump) |
Pumps |
4 |
Basement |
Byron Jackson |
Received 1973 / Model 12 MQ-10 STG / Serial No. 691-H-0911 / Capacity – 1,250 gpm / Speed – 1,770 rpm / Stages – 10 / Efficiency – ? % / Total Head – 630 ft. |
|
| HWP-42 |
1 |
Condenser Hotwell Pump (#42 HWP Pump) |
Pumps |
4 |
Basement |
Byron Jackson |
Received 1973 / Model 12 MQ-10 STG / Serial No. 691-H-0912 / Capacity – 1,250 gpm / Speed – 1,770 rpm / Stages – 10 / Efficiency – ? % / Total Head – 630 ft. |
|
| PCP-41 |
1 |
Plant Cooling Water Pump (#41 PCP Pump) |
Pumps |
4 |
Water Intake Area |
Worthington |
Model 15H277-1 / Serial No. VTP-31972 / Capacity – 3,000 gpm / Speed – 1,800 rpm / Stages – 1 / Efficiency – 80% / Total Head – 85 ft. |
|
| PCP-42 |
1 |
Plant Cooling Water Pump (#42 PCP Pump) |
Pumps |
4 |
Water Intake Area |
Worthington |
Model 15H277-1 / Serial No. VTP-31973 / Capacity – 3,000 gpm / Speed – 1,800 rpm / Stages – 1 / Efficiency – 80% / Total Head – 85 ft. |
|
| TLOR-41 |
1 |
Turbine Lube Oil Resevoir Assembly - Bearing Oil Pump (BOP-42) |
Pumps |
4 |
Mezz |
General Electric |
20 HP / ser#: FGJ61319 / 3510 RPM / mdl: 5K6228XH202A |
|
| TLOR-41 |
1 |
Turbine Lube Oil Resevoir Assembly - Emergency Turbine Oil Pump (ETOP-41) |
Pumps |
4 |
Mezz |
General Electric |
3500 RPM / 20 HP / ser#: RN-8-366-RN / mdl: 5CD183ZD840B800 / class F. |
|
| TLOR-41 |
1 |
Turbine Lube Oil Resevoir Assembly - Bearing Oil Pump (BOP-41) |
Pumps |
4 |
Mezz |
General Electric |
20 HP / 3545 RPM / mdl: 5K254DP126 / 460 volts / 26.9 amps |
|
| NOX-1 |
1 |
Combustion Tempering System Assembly - NOX-P-2 |
Pumps |
3 & 4 |
5 |
G&L Pumps |
10 HP / ser#: FO204151675 / 3450 RPM |
|
| NOX-1 |
1 |
Combustion Tempering System Assembly - NOX-P-1 |
Pumps |
3 & 4 |
5 |
G&L Pumps |
10 HP / ser#: FO204151740 / 3450 RPM |
|
| SOU-41 |
1 |
Seal Oil Unit Assembly - Emergency Seal Oil Pump (ESOP-41) |
Pumps / motors |
4 |
Basement |
General Electric |
Ser#: 5CD14031311 / 1750 RPM / 3 HP |
|
| SOU-41 |
1 |
Seal Oil Unit Assembly - Auxilary Seal Oil Pump (ASOP-41) |
Pumps / motors |
4 |
Basement |
General Electric |
ser#: 5K256AN379B / 1165 RPM / 10 HP |
|
| SOU-41 |
1 |
Seal Oil Unit Assembly - Seal Oil Vac Pump (HSOVP-41) |
Pumps / motors |
4 |
Basement |
General Electric |
Ser#: 7NA229FD2KA / 2 HP. |
|
| SWC-40 |
1 |
SWC Heat Exchanger - Pumps and motor |
Pumps / motors |
4 |
Basement |
General Electric Ingersoll Rand |
Motor = ser#: 5K256AL105C / 25 HP / 3520 RPM // Pump = ser#: 0171-124 / size: 2X8ATS / 3550 RPM. |
|
| SWC-40 |
1 |
SWC Heat Exchanger - Pumps and motor |
Pumps / motors |
4 |
Basement |
General Electric Ingersoll Rand |
Motor = ser#: 59152435 / 25 HP / 3520 RPM // Pump = ser#: 0171-123 / size: 2X8ATS / 3550 RPM. |
|
| TLOR-41 |
1 |
Turbine Lube Oil Resevoir Assembly - TRFP-41 |
Pumps / motors |
4 |
Mezz |
Allis Chalmers |
Pump = type: 2000 / size: 3X2X11 / ser#: 851-56633-01-1 / 100 gpm / 1750 RPM // Motor = mdl: RC21311FL7726APL / 1740 RPM |
|
| SOU-11 |
1 |
Seal Oil Unit Assembly (basement) Oil Cooler |
Seal Oil Unit |
1 |
Basement |
Westinghouse |
Size: 36, Ser. #: 16A1965-1, Instrument book: 1250-c497, max water pressure: 125 // Motor (ESOP-11) Ser. #: 357P673, 3 HP, Class 2. // Motor (HSOP-11) 2HP // Motor (GSE-11) Ser#: 5902 / 2 HP |
|
| SOU-21 |
1 |
Seal Oil Unit Assembly (basement) Oil Cooler |
Seal Oil Unit |
2 |
Basement |
Westinghouse |
Size: 36, Ser. #: 16A3512-1 / max water pressure: 125 // Motor (ESOP-21) Ser. #: IS-62 / 3 HP / Frame: 225 / Volts: 115 // Pump (ESOP-21) Ser #: 1H653-H1-62 // Motor (HSOP-21-c) Ser#: 1778550-6012 / 3HP / Mdl: ABEP / 3 Phase // Motor (HSOP-21-b) Ser#: 90F |
|
| SOU-31 |
1 |
Seal Oil Unit Assembly Oil Cooler |
Seal Oil Unit |
3 |
Basement |
?? |
Seal oil unit assembly with 2 motors |
|
| SOU-41 |
1 |
Seal Oil Unit Assembly Oil Cooler (H4-HSO-HSOVP-41) |
Seal Oil Unit |
4 |
Basement |
General Electric |
Seal oil unit assembly with 3 motors |
|
| GEN-11 |
1 |
Turbine 100 MW (H-TRB-LP-11) |
Steam Turbines |
1 |
TGB Room |
Westinghouse |
Built June 1959 / Design Conditions: Initial Pressure – 1.450 PSI / Initial Temp. 1,000° F.T.T. / Reheat Temp. 1,000° F.T.T. / Exhaust Temp. 1.5 IN.HG.ABS / Speed 3,600 RPM / Extraction Feedwater Heating – 5 Stages |
|
| GEN-21 |
1 |
Turbine 100 MW |
Steam Turbines |
2 |
TGB Room |
Westinghouse |
Built December 1962 / Design Conditions: Initial Pressure – 1,450 PSI / Initial Temp. 1,000° F.T.T. / Reheat Temp. – 1,000° F.T.T. / Exhaust Temp. 1.5 IN.HG.ABS / Speed 3,600 RPM / Extraction Feedwater Heating – 5 Stages |
|
| GEN-31 |
1 |
Turbine 165 MW |
Steam Turbines |
3 |
TGB Room |
Westinghouse |
Built June 1965 / Design Conditions: Steam Inlet Pressure – 1,800 PSIG / Steam Inlet Temp. – 1,000° F.T.T. / Reheat Temp. – 1,000° F.T.T. / Speed – 3,600 RPM / Exhaust Temp. – 2.0 IN.HG.ABS |
|
| GEN-41 |
1 |
Turbine 194 MW |
Steam Turbines |
4 |
TGB Room |
General Electric |
Rated 193,673 KW / 20 Stages / Speed – 3,600 RPM / Steam Pressure – 1,890 PSIG / Temperature – 1,000/1,000 °F / Exhaust Pressure – 2.5 inches H.G. ABS / No: 178843 |
|
|
1 |
Electro-Hydraulic Control Unit (EH System) EHC-41 |
Steam Turbines |
4 |
|
General Electric |
Fluid Reservoir / Twin Fluid Coolers / Air Dryer / A Pair of Hydraulic Accumulators / Space Heater / Auxiliary Filtering (AFC) |
|
| 2400SG-11 |
1 |
2400 Switchgear |
Switchgears |
1 |
|
Allis-Chambers Ruptair Power Circuit Breakers |
Model: Type MA-250A / Rated Volts: 4160 / Rated Amps: 1200 or 2000 / Hz: 60 / 5 – 2000 Amp breakers / 21 – 1200 Amp breakers / 2 spares (available for both switch gears) |
|
| 2400SG-21 |
1 |
2400 Switchgear |
Switchgears |
2 |
|
Allis-Chambers Ruptair Power Circuit Breakers |
Model: Type MA-250A-1 / Rated Volts: 4160 / Rated Amps: 1200 or 2000 / Hz: 60 / 5 – 2000 Amp breakers / 21 -1200 Amp breakers / 2 spares (available for both switch gears) |
|
|
2 |
480 Volt Load Center Switchgear |
Switchgears |
1 |
|
Allis/Chambers |
Breaker Types: LA-25A / 150A (5 ea.) / 200A (5 ea.) 400A (6 ea.) / 600A (6 ea.) / LA-50A / 1200A (4 ea.) / EMCC Breaker: Siemans-Allis / Type LA – 600A (5 ea.) / Dry Type Transformer Class AA / KVA: 750 / Volts: 2400H to 480X |
|
|
2 |
480 Volt Load Center Switchgear |
Switchgears |
3 |
|
GE Industrial Systems/GE AKD-10 Switchgear |
Dry Type Transformer Class AA/FA / KVA: 750/100 / 3 phase / Hertz: 60 / %IZ: Holly 3 – 5.81 / Holly 4 – 5.84 / Degree C Rise: 80 ° C / HV: 2,400 delta / 60 KV Bil / 180 -240 Amps / 6,500 lbs. / LV: 480 delta / 30 KV Bil / 902 – 1,202 Amps / 24 Load Center |
|
| 2400SG-31 |
2 |
2400 Switchgear |
Switchgears |
3 |
|
GE Power/Vac Switchgear |
Model: Type VB1 4.16-250 - 3 / Rated Max Volts: 4.76 KV / Rated Amps: 1200 or 2000 / Hz: 60 / Breakers: GE Power Vac Breakers / 6 – 2000 Amp breakers / 19 -1200 Amp breakers / 4 spares (available for both switch gears) |
|
| GSWT-11 |
1 |
Gland Seal Water Tank |
Tank |
1 |
4 |
?? |
no plate visible |
|
| GSWT-11 |
1 |
Gland Seal Water Tank |
Tank |
1 |
4 |
?? |
no plate visible |
|
|
3 |
Tank in Basement |
Tank |
1 |
Basement |
? |
Tank with 3 chambers |
|
| TLOR-11 |
1 |
Turbine Lube Oil Cooler Assbly |
Tank |
1 |
Mezz |
Westinghouse |
assembly with multiple pumps on top |
|
| DFWH-23 |
1 |
Cochrane Deaerator (H-DFWH-23) Tanks |
Tank |
2 |
4 |
Cochrane Corp. |
Shop order: 2999-61 / Max Press: 90 lbs |
|
| GSWT-21 |
1 |
Gland Seal Water Tank |
Tank |
2 |
4 |
?? |
no plate visible |
|
| LST-H21-23 |
3 |
Tank in Basement |
Tank |
2 |
Basement |
? |
Tank with 3 chambers |
|
| TLOR-21 |
1 |
Turbine Lube Oil Cooler Assbly |
Tank |
2 |
Mezz |
Westinghouse |
assembly with multiple pumps on top |
|
| LST-H31-33 |
3 |
Tank in Basement |
Tank |
3 |
Basement |
? |
Tank with 3 chambers |
|
| TLOR-31 |
1 |
Turbine Lube Oil Resevoir Assembly |
Tank |
3 |
Mezz |
Westinghouse |
Turbine Lube Oil Cooler Resevoir Assembly |
|
| CDT-41 |
1 |
Condensate Drain Tank |
Tank |
4 |
Sub-Basement |
Wyatt |
Year: 1972 / contract#: 414 / max working press: ATMOS / max temp: 700 deg F / ser#: 2389.71 |
|
| DFWH-44 |
2 |
Deaerator (H-DFWH-44) Tanks |
Tank |
4 |
4R - 4.5R |
Douglas and Lomason |
125 working pressure / 650 deg F / year 1971 / 23912 water gallons / ser#: 0061 / 114" diam / 0.625" sheet thick / 0.75" head thickness / 528" long // Tank 2 on top = year 1971 / 125 PSI @ 650 deg F / ser#: 0060 / 4667 water gallons / 78" diam / 216" long |
|
| IART-43 |
1 |
Instrument Air Resevoir Tank (IART-43) |
Tank |
4 |
Basement |
Wendland |
Year: 1972 / 100 PSI / 36" diam / 114" long / ser#: 15961 |
|
| LST-41-43 |
3 |
Turbine Oil Storage Tank (41-43) |
Tank |
4 |
Sub-Basement |
?? |
Tank with 3 chambers |
|
| STMT-41 |
1 |
Steam Tank |
Tank |
4 |
4R |
JJ Finnigan |
125 PSI @ 500 deg F / ser#: 27363 / year: 1976 |
|
| TLOR-41 |
1 |
Turbine Lube Oil Resevoir Assembly |
Tank |
4 |
Mezz |
?? |
no plate visible |
|
|
1 |
Acid Storage Tank, red |
Tank |
Demin Bldg |
Outside |
Houston Fabrications Inc. |
built: 1979/ Item# G04Z45/ DWG# 79-134 |
|
|
1 |
Flammable Gas Storage Tank, north tank, west of the main gas valves |
Tank |
Gas Valve Area |
Outside |
Gorbett Brothers Steel |
125 max PSI, built 1965, G-889 |
|
|
1 |
Flammable Gas Storage Tank, south tank, west of the main gas valves |
Tank |
Gas Valve Area |
Outside |
Trinity Steel Company |
125 max PSI, built 1959, S-1357, ser#: 3829 |
|
| AT-1 |
1 |
Auxiliary Power Transformer AT-1 |
Transformers |
1 |
Ground |
Westinghouse |
Tested June 1959 / Kva: 7,500 Voltage: 13,200/2,400 V |
|
| MT-1 |
1 |
Main Power Transformer MT-1 |
Transformers |
1 |
Ground |
Westinghouse |
Tested June 1959 / Kva: 140,000 / Voltage: 140,000/13,200 V |
|
| AT-2 |
1 |
Auxiliary Power Transformer AT-2 |
Transformers |
2 |
Ground |
Allis Chalmers |
Tested April 1962 / Kva: 7,500 / Voltage: 13,200/2,400 V |
|
| MT-2 |
1 |
Main Power Transformer MT-2 |
Transformers |
2 |
Ground |
General Electric |
Tested March 1962 / Kva: 140,000 / Voltage: 69,000/13,200 V |
|
| AT-3 |
1 |
Auxiliary Power Transformer AT-3 |
Transformers |
3 |
Ground |
Pennsylvania Transformer Division Mc-Graw Edison Co. |
Tested March 1965 / Kva: 7,500 / Voltage: 17,200/2,400 V |
|
| MT-3 |
1 |
Main Power Transformer MT-3 |
Transformers |
3 |
Ground |
General Electric |
Tested March 1965 / Kva: 220,000 / Voltage: 69,000/17,200 V |
|
| AT-4 |
1 |
Auxiliary Power Transformer AT-4 |
Transformers |
4 |
Ground |
McGraw-Edison Power Systems Division |
Tested 1972 / Kva: 7,500/8,400 / Voltage: 20,000/2,400 Delta V |
|
| MT-4 |
1 |
Main Power Transformer MT-4 |
Transformers |
4 |
Ground |
McGraw-Edison Power Systems Division |
Tested 1972 / Kva: 225,000/252,000 / Voltage: 69,000/20,000 V |
|
| ST-1 |
1 |
Start-up Power Transformer ST-1 |
Transformers |
1 & 2 |
Ground |
Westinghouse |
Tested July 1959 / Kva: 7,500 / Voltage: 69,000/2,400 V |
|
| ST-2 |
1 |
Start-up Power Transformer ST-2 |
Transformers |
3 & 4 |
Ground |
McGraw-Edison Power Systems Division |
Tested September 1972 / Kva: 7,500 / Voltage: 69,000/2,400 V |
|
| TWS-11 |
1 |
Intake Screen Assembly |
Water Screens |
1 |
Water Intake Area |
Link Belt |
Order: K6251 / mdl: 45 |
|
| TWS-12 |
1 |
Intake Screen Assembly |
Water Screens |
1 |
Water Intake Area |
Link Belt |
Order: K6251 / mdl: 45 |
|
| TWS-21 |
1 |
Intake Screen Assembly |
Water Screens |
2 |
Water Intake Area |
?? |
RS362 welded on unit frame |
|
| TWS-22 |
1 |
Intake Screen Assembly |
Water Screens |
2 |
Water Intake Area |
?? |
RS361 welded on unit frame |
|
| TWS-31 |
1 |
Intake Screen Assembly |
Water Screens |
3 |
Water Intake Area |
Screen Systems International |
Ser#: WS-3640 / mdl: 2PV-1031-2B / size: 10'X31' / type: "Thru Flow TWS11" |
|
| TWS-32 |
1 |
Intake Screen Assembly |
Water Screens |
3 |
Water Intake Area |
Screen Systems International |
Ser#: WS-3673 / mdl: 2PV-1031-2B / size: 10'X31' / type: "Thru Flow TWS11" |
|
| TWS-41 |
1 |
Intake Screen Assembly |
Water Screens |
4 |
Water Intake Area |
?? |
No tag visible |
|
| TWS-42 |
1 |
Intake Screen Assembly |
Water Screens |
4 |
Water Intake Area |
?? |
No tag visible |
|
| CFP-41 |
1 |
Chemical Feed Pump |
Pump |
Bldg. J |
Mezz |
Pulsa |
Ser#: G7741//Mtr = Allis Chambers / 5 HP / Ser#: 51-303-065 / 1740 |
|
| CFP-42 |
1 |
Chemical Feed Pump |
Pump |
Bldg. J |
Mezz |
Pulsa |
Ser#: G7742 // Mtr = WEG / 1750 rpm / 5 HP |
|
| CFP-31 |
1 |
Chemical Feed Pump |
Pump |
Bldg. J |
Mezz |
Pulsa |
Ser#: 9476262-1 / mdl: 8480 / Gear Ratio 29 / max press: 3,200 PSIG / max flow: 15.3 gph // Mtr = Baldor / 3 HP / 1725 rpm / 208 volts. |
|
| 2400SG-41 |
2 |
2400 Switchgear |
Switchgears |
4 |
|
GE Power/Vac Switchgear |
Model: Type VB1 4.16-250 - 3 / Rated Max Volts: 4.76 KV / Rated Amps: 1200 or 2000 / Hz: 60 / Breakers: GE Power Vac Breakers / 6 – 2000 Amp breakers / 19 -1200 Amp breakers / 4 spares (available for both switch gears) |
|
|
2 |
480 Volt Load Center Switchgear |
Switchgears |
2 |
|
Allis/Chambers |
Breaker Types: LA-25A / 150A (5 ea.) / 200A (5 ea.) 400A (6 ea.) / 600A (6 ea.) / LA-50A / 1200A (4 ea.) / EMCC Breaker: Siemans-Allis / Type LA – 600A (5 ea.) / Dry Type Transformer Class AA / KVA: 750 / Volts: 2400H to 480X |
|
|
2 |
480 Volt Load Center Switchgear |
Switchgears |
4 |
|
GE Industrial Systems/GE AKD-10 Switchgear |
Dry Type Transformer Class AA/FA / KVA: 750/100 / 3 phase / Hertz: 60 / %IZ: Holly 3 – 5.81 / Holly 4 – 5.84 / Degree C Rise: 80 ° C / HV: 2,400 delta / 60 KV Bil / 180 -240 Amps / 6,500 lbs. / LV: 480 delta / 30 KV Bil / 902 – 1,202 Amps / 24 Load Center |
|